Structure, control and sizing calculations for a dual-lane synchronous-belt conveyor handling 314 Ah cells
Introduction: Cell Conveying Is an Overlooked Factor in Production Yield
As energy-storage manufacturing expands, large-format prismatic aluminum-case lithium iron phosphate (LFP) cells, including 314 Ah models, have become common in storage systems. From electrolyte filling, formation and capacity grading to open-circuit voltage (OCV) testing, module assembly and PACK assembly, each cell moves between many stations. The conveyor may add no direct process value, but it links every step. Its performance affects line throughput, cell appearance and safety, and the positioning consistency needed for reliable robotic pickup and equipment handoff.
This article examines a completed dual-lane synchronous-belt conveyor design for 314 Ah prismatic cells. It covers the conveyed product, conveyor selection, mechanical structure, control sequence, and motor and pneumatic-cylinder sizing as a reference for battery-line integrators and equipment engineers.
1. The Conveyed Product: Physical Characteristics of a 314 Ah Prismatic Cell
The first design task is to understand the cell. The 314 Ah LFP cell used for this line has a prismatic aluminum case, weighs approximately 5.6 kg, measures about 72 mm (thickness) × 174 mm (width) × 207 mm (height), and has a nominal voltage of 3.2 V. Positive and negative terminals and a pressure-relief vent are located on top. Because the cell is electrically live while being transferred, the conveyor faces constraints unlike those for ordinary metal parts:
- The aluminum case is wrapped in blue insulating film. Scratches or impacts can damage the film or dent the case, causing the cell to be downgraded or scrapped.
- No load should be applied to the top terminals, vent or electrolyte-filling port, and metal parts must not bridge these areas.
- A vertically conveyed cell has a high center of gravity and a narrow footprint. It needs lateral guidance without rigid clamping.
- The machine handles electrically live parts, so electrostatic discharge (ESD), short circuits, metal contamination and cleanliness must be addressed throughout the design.
Accordingly, the guide width is continuously adjustable from 54 to 80 mm. It accommodates the approximately 72 mm-thick 314 Ah cell and other thicknesses in the same family, improving equipment reuse.
2. Five Special Requirements for Prismatic-Cell Conveying
Compared with conveyors for consumer electronics, packaging or metal parts, a bare-cell conveyor has five particular requirements.
1. Prevent impacts and compression. A defect-free cell exterior is a firm requirement. Contact parts should use compliant materials such as rubber coating, polyurethane or engineering plastics. Lateral guides should use rolling rather than sliding contact, and cells must not collide rigidly during stopping or accumulation.
2. Control electrostatic discharge. Continuous contact between the belt and cell can generate static electricity, attracting dust and potentially damaging the cell. As described in the source design, cell-contact belts and supports use antistatic materials with a typical surface-resistance target of 10^6–10^9 Ω. Conductive wheels and grounding terminals provide a continuous, reliable discharge path along the line.
3. Prevent short circuits and metal contamination. If a metal part bridges the positive and negative terminals of a live cell, it can cause an immediate short circuit. Copper and iron particles present added risk in a dry environment. Exposed metal should not contact the terminal area, and the machine should minimize dirt traps and allow easy cleaning.
4. Maintain cleanliness and low particle generation. Cell workshops are often dry, clean environments. Belt materials should have low outgassing and low wear debris, such as antistatic polyurethane (PU), and resist media including electrolyte. Drives with metal-on-metal contact or substantial particle shedding should be kept away from exposed cells.
5. Position cells accurately and accumulate them at the required takt. Formation, capacity grading, OCV testing and robotic pickup require cells to stop at defined positions. This design specifies machining and positioning accuracy of ±0.5 mm. When a downstream station is busy, upstream cells must accumulate without compressing one another.
3. Conveyor Selection: Why Use Synchronous Belts for the Cell Section?
Three common conveyor types in battery production are accumulating chains with pallets, powered rollers, and synchronous or flat belts. Their applications differ, as Table 1 shows.
Table 1. Comparison of Three Common Battery-Line Conveyor Types
| Conveyor type | Load characteristics | Positioning and takt | Suitability for cells | Typical application |
|---|---|---|---|---|
| Accumulating chain + pallet | High load capacity; pallets carry heavier modules | Mature stop-cylinder positioning; stable takt | The pallet separates the chain from the cell, but requires pallet return, more floor space and higher cost | Main module/PACK assembly line |
| Powered rollers | Suitable for long distances and heavy loads; simple, low-cost structure | Greater stopping impact; moderate positioning accuracy | Numerous metal rollers and open gaps make direct bare-cell conveying unsuitable | Heavy-load movement of packs and enclosures |
| Synchronous/flat belt | Light to medium loads; smooth, quiet operation | Easy integration with stops and sensors for accurate positioning | Antistatic compliant contact materials can protect insulating film and support cleanliness | Bare-cell feeding and process links (this design) |
This line carries bare cells a short distance between processes and stops them accurately at workstations. Its load is relatively light, its takt is fast, and appearance and cleanliness matter. It therefore uses two parallel synchronous belts in a dual-lane arrangement. An accumulating chain can be reserved for a later module-assembly section carrying heavier loads.
4. System Overview: Dual-Lane Synchronous-Belt Conveyor
The machine measures approximately 1,100 mm (L) × 240 mm (W) × 634 mm (H), including adjustable feet, and provides about 1,000 mm of effective conveying length. As Figure 1 shows, two parallel belts form two conveying lanes. Cells travel upright, supported at both sides of their bases, with their center of gravity between the belts. Adjustable side guides, pneumatic stop stations and through-beam photoelectric sensors run along the line. At one end, an AC variable-speed motor drives the main shaft through a gearbox and timing belt, synchronizing both lanes.

Table 2. Main Conveyor Specifications
| Item | Specification / configuration |
|---|---|
| Workpiece | 314 Ah prismatic LFP cell; approximately 5.6 kg each |
| Conveyor arrangement | Dual-lane S5M synchronous belts; upright cells supported from beneath by two belts |
| Adjustable guide width | 54–80 mm, continuously adjustable |
| Overall dimensions (L × W × H) | Approx. 1,100 × 240 × 634 mm, including adjustable feet |
| Effective conveying length | Approx. 1,000 mm |
| Target belt speed | 25 mm/s (approx. 1.5 m/min) |
| Design throughput | Approx. 20 cells/min |
| Stop-and-position cycle | 6 s per station |
| Machining/positioning accuracy | ±0.5 mm |
| Operating air pressure | 0.5 MPa |
| Power supply | AC 220 V / 50 Hz |
| Full-line load | Approx. 44.4 kg, based on eight cells |
| Main sensors | Six through-beam photoelectric switches; two proximity switches |
| Stop actuators | Six miniature cylinders, 16 mm bore × 20 mm stroke |
5. Mechanical Design in Detail
5.1 Aluminum-Profile Frame and Adjustable Feet
The main frame uses 30 × 60-series industrial aluminum profiles made of 6061 aluminum alloy with a natural matte anodized finish. Corner brackets, profile nuts and sliding nuts connect the frame without welding. This avoids rust, speeds assembly, and allows later changes to guide width or sensor stations without rewelding. Four adjustable feet, each 60 mm in diameter with an M12 adjustment screw, level the line during installation. Frame stiffness also provides a reference for aligning the drive and idler pulley shafts. Anodized coating is electrically insulating, however, so ESD grounding requires dedicated grounding terminals or conductive connections. An aluminum frame alone does not guarantee grounding.

5.2 Dual-Lane Conveying and Drive System
Two parallel S5M synchronous belts form the conveying surface. The end pulleys are specified for 80 mm-wide belts, with a pitch diameter of approximately 40 mm. A T5 timing belt transmits power from the motor end to the drive shaft; synchronous pulleys at both ends of that shaft then drive the two conveyor belts at the same speed. This helps prevent cells from rotating or drifting sideways.
Supporting the carrying and return runs is a key design issue for this narrow-belt line. More than 200 rubber-coated bearings support the belts and their edges, with six additional rubber-coated rollers. Rolling contact reduces friction, motor load and belt wear while helping the line run quietly. The drive and idler shafts use chrome-plated 45 steel; the shaft mounts and tensioning seats are anodized 6061 aluminum alloy. Adjustment screws at the ends change the idler-pulley center distance to tension both belts evenly and limit tooth skipping and belt tracking errors.

5.3 Adjustable-Width Guide Assembly
Because the cell is tall and narrow, the guides must steady it without squeezing it. Guide shafts, support blocks, clamps and vertical rods form the lateral assemblies. Loosening the clamps allows continuous adjustment and locking across a 54–80 mm width range, without replacing parts during a changeover. Closely spaced rubber-coated bearings along the rails provide rolling contact with the cell sides. They correct cell attitude without scratching the insulating film. A central guard rail further limits abnormal cell movement.
5.4 Pneumatic Stopping and Positioning Assembly
Six identical stop units are arranged along the line. Each comprises a support plate, a fork-shaped stopper block made of 6061 aluminum alloy, and a miniature cylinder with a 16 mm bore, 20 mm stroke and magnetic position detection. When a cylinder extends, the block rises and stops the incoming cell while the soft belt continues moving under it. A through-beam sensor confirms arrival, and the cell waits for downstream release. The cylinder then retracts to let the cell proceed. Each cylinder has an independent flow-control valve to adjust its extension and retraction speed and cushion contact.
5.5 Detection and Control
Six through-beam photoelectric switches detect cell arrival and station occupancy; two proximity switches confirm positions at the inlet and end. A programmable logic controller (PLC) coordinates the solenoid valves in the sequence ‘detect occupancy → hold stop → receive downstream release → retract stop’ to create zero-pressure accumulation. An upstream stop remains engaged while the downstream station is unavailable, keeping cells separated. The motor can run continuously; the stop units handle station timing without frequent motor starts and stops.
6. Operating Cycle and Throughput Analysis
- A synchronous belt carries a cell to the corresponding stop station.
- A through-beam sensor detects the cell. With the cylinder extended, the cell is stopped and positioned while it waits for the downstream process.
- When the preceding cell has been removed or the downstream station permits release, the cylinder retracts and the cell advances to the next stop.
- A new cell enters at the inlet, where a proximity switch confirms entry; the sequence repeats.
A single-station stop-and-release cycle takes approximately 6 s. At a belt speed of 25 mm/s and a theoretical pitch of about 72 mm in the cell-thickness direction, the theoretical flow rate is 25 ÷ 72 × 60 ≈ 20.8 cells/min, close to the design target of 20 cells/min. Continuous belt speed governs the theoretical flow rate; the stops provide station-level positioning and accumulation.
7. Key Component Sizing Calculations
The motor and stopper-cylinder calculations below reproduce the parameters and conclusions in the original project design files.
7.1 Drive-Motor Selection
Table 3. Motor-Sizing Inputs
| Input parameter | Symbol | Value |
|---|---|---|
| Total load mass (eight cells on a full line) | M | 44.4 kg |
| Target belt speed | V | 25 mm/s |
| Acceleration time | t | 1.5 s |
| Coefficient of friction | μ | 0.5 |
| Transmission efficiency | η | 0.7 |
| Gear reduction ratio | i | 30 |
| Drive-pulley pitch diameter | D | 38 mm |
| Safety factor | K | 2 |
| Gravitational acceleration | g | 9.8 m/s² |
1. Maximum required motor speed based on the drive pulley:
n = V × i / (π × D) = 25 × 30 / (3.14 × 38) ≈ 6.28 r/s ≈ 377 r/min
2. Steady-state load force, including friction and a safety factor:
F = M × g × μ × K = 44.4 × 9.8 × 0.5 × 2 ≈ 435.1 N
3. Required motor-shaft working torque, accounting for reduction and transmission efficiency:
T = F × D / (2 × i × η) = 435.1 × 0.038 / (2 × 30 × 0.7) ≈ 0.394 N·m
4. During acceleration, angular acceleration is approximately 26.3 rad/s² and the corresponding acceleration torque is about 0.0007 N·m, much smaller than the steady-friction torque. In this calculation, friction dominates the load and startup inertia is not the limiting factor.
5. Calculated power requirement:
P = T × n / 9.55 = 0.394 × 377 / 9.55 ≈ 15.5 W
The design selects a 220 W AC variable-speed motor with a 30:1 gear reducer. The source design lists approximately 0.53 N·m starting torque and 0.75 N·m continuous allowable torque at the motor output, both above the calculated 0.394 N·m requirement. It therefore judges the selection acceptable, with capacity for long service life and stable low-speed operation.
Table 4. Motor-Sizing Results and Checks
| Calculated / checked item | Result | Assessment |
|---|---|---|
| Maximum motor speed n | Approx. 377 r/min | — |
| Load force F | Approx. 435.1 N | — |
| Required working torque T | Approx. 0.394 N·m | — |
| Calculated power P | Approx. 15.5 W | — |
| Starting torque at motor output | Approx. 0.53 N·m | 0.53 > 0.394; passes |
| Continuous allowable motor torque | Approx. 0.75 N·m | Adequate margin |
7.2 Stopper-Cylinder Selection
Table 5. Stopper-Cylinder Sizing Inputs
| Input parameter | Value |
|---|---|
| Equivalent load per stop M | 0.5 kg |
| Operating pressure P | 0.5 MPa |
| Coefficient of friction μ | 0.1 |
| Load factor (safety factor) η | 0.5 |
| Working stroke L | 20 mm |
| Actuation time | Approx. 0.5 s (0.1 s each for starting and stopping) |
The stopper operates over a short horizontal stroke with a small effective load. Using F = (π/4) × d² × P × η, the source calculation estimates that a bore of about 6 mm would supply approximately 5 N at 0.5 MPa and a 0.5 load factor. The chosen miniature cylinder has a 16 mm bore and 20 mm stroke. Its calculated theoretical force is F = (π/4) × 0.016² × 0.5 × 10⁶ × 0.5 ≈ 50.3 N. The bore is more than 2.7 times the estimated minimum, providing capacity for minor impact when a cell reaches the stop and for repeated operation.
8. Design Checklist and Common Pitfalls
- Alignment: The drive and idler pulley axes must be parallel and perpendicular to the conveying centerline; otherwise, the belts can drift and cells can travel at an angle. Align the aluminum-profile frame against reference surfaces. The source design targets frame parallelism on the order of 0.1 mm/m.
- Tensioning: Match tension at both sides. After installation, run the line empty and check belt tracking, bearing temperature rise and motor current before testing with cells.
- Contact materials: Use rubber-coated or nonmetallic parts such as PU and POM wherever the conveyor contacts a cell; do not let exposed metal scratch the insulating film. Specify an antistatic PU or special-rubber belt with 10^6–10^9 Ω surface resistance and electrolyte resistance.
- ESD: Provide a continuous, reliable grounding path through the frame. Combine antistatic belts with conductive wheels or grounding brushes to discharge static electricity.
- Accumulation: Program the sequence to confirm station occupancy before releasing a stop. If a downstream station cannot accept a cell, hold the upstream cell to prevent rear-end collisions.
- Cushioning: Use flow-control valves to regulate cylinder speed. Prefer POM or polyurethane buffers at stopper heads and end stops to absorb impact.
- Maintenance: Mount rubber-coated bearings, belts and cylinders as replaceable modules. Leave adjustment range for sensor positions.
- Sizing margin: The source design applies conservative friction and safety factors to the motor and cylinder. It calculates about 16 W of motor power and a stopper-cylinder bore more than 2.7 times the estimated minimum, trading size margin for operating stability and service life.
9. Conclusion
A cell conveyor must move cells steadily, position them accurately, stay clean and handle them gently. Compliant contact and rolling guides protect cell appearance; ESD and short-circuit precautions address safety; photoelectric sensors and pneumatic stops provide positioning and zero-pressure accumulation; and standard aluminum profiles and drive and pneumatic components make the line modular and adaptable. The 314 Ah dual-lane conveyor described here is designed for about 20 cells/min, ±0.5 mm positioning and a 54–80 mm cell-thickness range. Its layout can inform links between capacity grading, OCV testing and PACK feeding, as well as adaptations for larger-format cells.
References
[1] REPT BATTERO, 314Ah Battery Cell product data (71 × 173 × 207 mm; 5.6 kg).
[2] CATL, 314Ah 3.2V LiFePO4 Prismatic Cell specification (174.26 × 204.41 × 71.65 mm).
[3] China Industrial Control Network, 2026 review of light industrial conveyor belts for electronics (antistatic-belt surface resistance of 10^6–10^9 Ω; low-particle TPU).
[4] Instrument.com.cn, technical specifications for new-energy/lithium-battery synchronous-belt conveyor lines (0.1–1.0 m/s speed, ≤60 kg load per section, alignment and tensioning).
[5] Xianning News Network, comparison of accumulating-chain, belt and flexible-chain conveying for prismatic battery PACK/module lines.
[6] Dorner Conveyors, ‘The EV Battery Clean & Dry Mandate’ (ESD grounding paths, metal contamination and clean/dry requirements).
[7] BLCH Pneumatic, stop-cylinder and photoelectric-sensor spacing/indexing logic for accumulation.
[8] Lingrui Intelligent, synchronous-belt conveyor lines for new-energy battery modules (flame-retardant antistatic PU belts and electrolyte resistance).